Clinical Applications

       We have initially focused our clinical and commercial efforts on applications of the Stereotaxis System in complex interventional cardiology procedures for the treatment of coronary artery disease, and in electrophysiology procedures for the treatment of arrhythmias. Our system potentially has broad applicability in other areas, such as interventional neurosurgery, interventional neuroradiology, peripheral vascular, pulmonology, urology, gynecology and gastrointestinal medicine, and our patent portfolio has been structured to permit expansion into these areas.

 
Interventional Cardiology

       Nearly half a million people die annually from coronary artery disease, a condition in which the formation of plaque in the coronary arteries obstructs the supply of blood to the heart, making this the leading cause of death in the U.S. Despite various attempts to reduce risk factors, each year over one million patients undergo interventional procedures in an attempt to open blocked vessels and another half a million patients undergo open heart surgery to bypass blocked coronary arteries.

       Blockages within a coronary artery, often called lesions, are categorized by degree of obstruction as partial occlusions, non-chronic total occlusions and chronic total occlusions. Lesions are also categorized by the degree of difficulty with which they can be opened as simple or complex. If the blockage is in an easy to reach location, it can typically be treated by pushing a guidewire through the portion of the vessel that is blocked with plaque, expanding a small balloon to compress the plaque against the artery walls in order to open the artery, and then finally deploying a stent, which is a small metal scaffold, to help keep the artery open. If a blockage is located within tortuous vasculature, however, the physician must navigate the guidewire through a series of sharp turns, making the blockage very difficult to reach. Even if such lesions are reached, delivering a balloon or stent to the treatment site through tortuous anatomy can be difficult. In addition, complex lesions, such as chronic total occlusions, longer lesions, and lesions located within smaller diameter vessels, are often very difficult or time consuming to open with manual interventional techniques.

       Physicians are currently performing approximately 1.8 million interventional cardiology procedures worldwide each year, and we estimate that approximately 15%, or 270,000, of these procedures are complex and therefore require longer procedure times and may have sub-optimal outcomes. We believe that our system can substantially benefit this subset of complex interventional cardiology procedures, including procedures involving:

Complex partial occlusions, complex non-chronic total occlusions and chronic total occlusions. Treatment of these complex lesions is generally more problematic due to the difficulty in steering and pushing a guidewire through them. Because our system provides precise computerized control of the working tip of a guidewire, it can enable physicians to more easily locate small openings in, and to advance a guidewire across, these lesions. Also, our magnetically steerable microcatheter can help steer a variety of conventional wire products, some of which are designed to cross complex lesions, but which otherwise lack the controlled steering needed to avoid perforating the vessel wall. The ability to cross complex lesions such as chronic total occlusions has grown increasingly important due to the effectiveness of drug eluting stents in treating these lesions. Since approximately one-fifth of patients referred to bypass surgery have chronic total occlusions, we believe a significant number of patients could be treated interventionally instead of surgically if more of these lesions could be opened for stenting.
 
Tortuous Anatomy. We estimate that between 10 and 15% of all interventional procedures require physicians to navigate a disposable interventional device through a series of sharp turns in the patient’s vasculature. Navigating through tortuous anatomy using manual interventional techniques can be very time consuming and physicians often cannot reach the lesion or manipulate the balloon or stent across the lesion once it is reached. Because our system allows the working tip of disposable interventional devices to be precisely oriented

55